Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV circuits. 
N/A 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
2.7.1 
C: Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-
circuits and earth faults in 
PRIMARY CIRCUITS
protective devices shall be included either as 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), 
b) and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as parts of 
the equipment; 
b) for components in series with the mains input 
to the equipment such as the supply cord, 
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided 
by protective devices in the building installation; 
c) it is permitted for 
PLUGGABLE EQUIPMENT TYPE
 B 
or 
PERMANENTLY CONNECTED EQUIPMENT
, to rely 
on dedicated overcurrent and short-circuit 
protection in the building installation, provided 
that the means of protection, e.g. fuses or circuit 
breakers, is fully specified in the installation 
instructions. 
If reliance is placed on protection in the building 
installation, the installation instructions shall so 
state, except that for 
PLUGGABLE EQUIPMENT TYPE 
A the building installation shall be regarded as 
providing protection in accordance with the rating 
of the wall socket outlet. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
 
S (GB): To protect against excessive currents 
and short-circuits in the 
PRIMARY CIRCUIT 
of
 
DIRECT PLUG
-
IN EQUIPMENT
, protective devices 
shall be included as integral parts of the 
DIRECT 
PLUG
-
IN EQUIPMENT
Not a Direct Plug-In Equipment.
N/A 
2.7.2 C: 
Void. 
Considered. 
— 
2.10.2 
C: Replace in the first line "(see also 1.4.7)" by 
"(see also 1.4.8)". 
Considered. — 