- Page 33 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004)
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004)
General
C: Delete all the "country" notes in the reference
document according to the following list:
document according to the following list:
1.1.5
Note 2
1.5.8
Note 2
1.6.1 Note
1.7.2 Note
4 1.7.12 Note
2 2.1 Note
2.2.3
Note
2.2.4
Note
2.3.2 Note 2, 7, 8
2.3.3
Note 1, 2 2.3.4
Note 2,3 2.7.1 Note
2.10.3.1 Note 4
3.2.1.1 Note
3.2.3 Note 1, 2
3.2.5.1 Note
2
4.3.6
Note
1,2 4.7.2.2 Note
4.7.3.1 Note
2
6.1.2.1 Note
6.1.2.2 Note
6.2.2 Note
6.2.2.1 Note
2 6.2.2.2
Note
7 Note
4
7.1 Note
G2.1
Note 1, 2 Annex H Note 2
Considered.
—
1.2.4.1
S (DK): Certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
1.5.1
A (SE, Ordinance 1990:944) and
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
NOTE – Switches containing mercury such as thermostats,
relays and level controllers are not allowed.
relays and level controllers are not allowed.
There are no components
containing mercury in the
equipment.
containing mercury in the
equipment.
N/A
1.5.8
S (NO): Due to the IT power system used (see
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
1.7.2
S (FI, NO, SE): C
LASS
I
PLUGGABLE EQUIPMENT
TYPE
A intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan"
koskettimilla varustettuun pistorasiaan"
—
NO: "Apparatet må tilkoples jordet stikkontakt"
—
SE: "Apparaten skall anslutas till jordat uttag"
—
A (DK, Heavy Current Regulations): Supply cords
of
of
CLASS
I
EQUIPMENT
, which is delivered without
a plug, must be provided with a visible tag with
the following text:
the following text:
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A