ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 78

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

IEC 60950-1 (ed.1)
 
Page 6 of 7
 - 
 
 
www.nemko.com
 
Report No.  100711 
 
U.2.3 
Replacement:
 
Replace the first paragraph with the following. 
Test 9 of IEC 60851-6:1996, followed by the electric 
strength test of 5.2.2 of this standard except applying 
the test voltage between the wire and the mandrel. A 
test voltage shall be the appropriate voltage in table 5B 
(see 5.2.2) of this standard. 
However, the minimum values shall be as follows: 
 
- for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 1500 V, or; 
- for REINFORCED INSULATION, 3000 V. 
Not TIW used. 
 
U.2.4 
Replacement:
 
Replace the third paragraph describing the test voltage 
with the following. 
The test voltage shall not be less than the appropriate 
voltage in table 5B (see 5.2.2) of this standard. 
However, the minimum values shall be as follows: 
 
- for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 1500 V, or; 
 
- for REINFORCED INSULATION, 3000 V. 
It is applied between the shot and the conductor. 
 
Not TIW used. 
 
U.3.1 
Replacement:
 
Replace with the following. 
The test voltage for ROUTINE TESTING shall be the 
appropriate voltage in table 5B (see 5.2.2) of this 
standard. Howeve, the minimum values shall be as 
follows: 
 
- for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 1500 V r.m.s. or 2100 V peak, or; 
 
- for REINFORCED INSULATION, 3000 V r.m.s. or 
4200 V peak. 
 
Not TIW used. 
 
Page of 87
Display