IEC 60950-1 (ed.1)
- Page 5 of 5 -
www.nemko.com
Report No. 100711
TRF No. IECEN60950_1C
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
No TNV circuitry.
N
2.6.3.4
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class III equipment.
N
3.2.1.2
Equipment connected to centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N
4.2.8.1
Enclosures around CRT’s with a face diameter of
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
No CRTs in the equipment.
N
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
No handles.
N
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
No TNV circuitry.
N
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
No TNV circuitry.
N
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV circuitry.
N
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
No TNV circuitry.
N
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuitry.
N