Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online
- Page 12 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
Test by inspection ................................................. :
⎯
Test with test finger (Figure 2A) ........................... :
⎯
Test with test pin (Figure 2B) ................................ :
⎯
Test with test probe (Figure 2C) ........................... :
⎯
2.1.1.2
Battery compartments
No TNV circuits in the
equipment.
equipment.
N
2.1.1.3
Access to ELV wiring
No internal wiring at ELV.
N
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
⎯
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N
2.1.1.5 Energy hazards ..................................................... :
Class III equipment.
N
2.1.1.6 Manual
controls
No shafts or konbs.
N
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N
Measured voltage (V); time-constant (s) ............... :
⎯
2.1.1.8
Energy hazards – d.c. mains supply
Class III equipment, supplied
from SELV.
from SELV.
N
a) Capacitor connected to the d.c. mains supply . :
⎯
⎯
2.1.1.9 Audio
amplifiers .................................................... :
Considered. Also refer to
Summary of Testing.
Summary of Testing.
P
2.1.2
Protection in service access areas
Class III equipment
N
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N
2.2 SELV
circuits
⎯
2.2.1 General
requirements
Class III equipment.
SELV limits are not exceeded
under normal condition and
after a single fault.
SELV limits are not exceeded
under normal condition and
after a single fault.
P
2.2.2
Voltages under normal conditions (V) .................. :
Within SELV limits.
P
2.2.3
Voltages under fault conditions (V) ...................... :
Within SELV limits.
P
2.2.4
Connection of SELV circuits to other circuits ......:
SELV circuits are only
connected to other SELV
circuits.
connected to other SELV
circuits.
P
2.3 TNV
circuits
⎯
2.3.1 Limits
No TNV circuits.
N
Type of TNV circuits .............................................. :
⎯
Click on the first or last page to see other ON STAGE 400P (serv.man4) service manuals if exist.