Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online
- Page 11 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
1.7.2.5
Operator access with a tool
N
1.2.7.6 Ozone
The equipment does not
produce Ozone.
produce Ozone.
N
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N
1.7.4 Supply
voltage adjustment .................................. :
No voltage selector.
N
Methods and means of adjustment; reference to
installation instructions ........................................ :
installation instructions ........................................ :
N
1.7.5 Power
outlets
on the equipment .......................... :
No standard power outlet.
N
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ......................... :
characteristics, cross-reference) ......................... :
No fuses
N
1.7.7 Wiring
terminals
Class III equipment.
N
1.7.7.1 Protective
earthing and bonding terminals .......... :
N
1.7.7.2
Terminals for a.c. mains supply conductors
N
1.7.7.3
Terminals for d.c. mains supply conductors
N
1.7.8
Controls and indicators
Refer below.
—
1.7.8.1 Identification,
location and marking ..................... :
No controls or figures
affecting safety provided.
affecting safety provided.
N
1.7.8.2 Colours ............................................................... :
For functional indication a
LED lights when the
equipment is operating.
LED lights when the
equipment is operating.
N
1.7.8.3 Symbols
according to IEC 60417 .........................:
A stand-by condition is
indicated by the symbol
according to IEC 60417-5009.
indicated by the symbol
according to IEC 60417-5009.
P
1.7.8.4 Markings
using figures ........................................:
N
1.7.9
Isolation of multiple power sources .....................:
Class III equipment.
N
1.7.10
Thermostats and other regulating devices ..........:
Class III equipment.
N
1.7.11 Durability
The marking withstands
required tests.
required tests.
P
1.7.12 Removable
parts
No removable parts.
P
1.7.13 Replaceable
batteries ..........................................:
No battery in the equipment.
N
Language(s) .........................................................:
⎯
1.7.14
Equipment for restricted access locations............:
Equipment not intended for
installation in RAL.
installation in RAL.
N
2
PROTECTION FROM HAZARDS
⎯
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
Refer below:
⎯
2.1.1.1
Access to energized parts
Class III equipment.
N