Report No. 98323
1.5.1
Some components and materials associated with
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements.
These components include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, surge suppressors, switches
(including interlock switches), thermal cutoffs,
thermostats, multi-layer transformer winding wire,
tubing, wire connectors, and wire and cables
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements.
These components include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, surge suppressors, switches
(including interlock switches), thermal cutoffs,
thermostats, multi-layer transformer winding wire,
tubing, wire connectors, and wire and cables
Critical components are IEC
certified. See list of critical
components in main CB report
(§1.5.01). There may be
additional requirements for
components in USA.
certified. See list of critical
components in main CB report
(§1.5.01). There may be
additional requirements for
components in USA.
P
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vdc, the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vdc, the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
No TNV circuitry.
N
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
No TNV circuitry.
N
2.6.3.4
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class III equipment.
N
3.2.1.2
Equipment connected to centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
The equipment is not for
connection to a d.c. mains
supply.
connection to a d.c. mains
supply.
N
4.2.8.1
Enclosures around CRT’s with a face diameter of
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
No CRTs in the equipment.
N
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
The equipment has no handles.
N