Read JBL ON CALL (serv.man2) EMC - CB Certificate online
Page 11 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
Note:
The output of the power supply complies with the requirement of inherently Limited Power Source.
Model MU15-C033280-C5:
Limits: Isc
≤ 8.0 A, S ≤ 17.40 VA (5 x Uoc).
Measured Uoc = 3.48 Vdc, Isc = 4.15 A, S = 11.5 VA (2.77 Vdc
× 4.15 A), under the maximum normal
operation (the worst case include single faults).
Model MU15-C060250-C5:
Limits: Isc
≤ 8.0 A, S ≤ 30.25 VA (5 x Uoc).
Measured Uoc = 6.05 Vdc, Isc = 4.17 A, S = 22.6 VA (5.42 Vdc
× 4.17 A), under the maximum normal
operation (the worst case include single faults).
Model MU15-C240010-C5:
Limits: Isc
≤ 8.0 A, S ≤ 100 VA. (5 x Uoc).
Measured Uoc = 24.04 Vdc, Isc = 1.83 A, S = 43.4 VA (23.71 Vdc
× 1.83 A), under the maximum normal
operation (the worst case include single faults).