ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits....... : SELV circuits only connected to
SELV circuits
P
Note:
Model MU15-C240010-C5:
The voltage measured between T1, pin A-B is 66.8 Vpeak
The voltage measured between T1 after D7 is 24.1 Vdc
2.3 TNV
circuits
2.3.1
Limits
No TNV circuit within the EUT
N/A
Type of TNV circuits............................................ :
2.3.2
Separation from other circuits and from
accessible parts
accessible parts
N/A
Insulation
employed ............................................ :
2.3.3 Separation
from hazardous voltages
N/A
Insulation
employed ............................................ :
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation
employed ............................................ :
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
2.4.1 General
requirements
P
2.4.2 Limit
values
P
Frequency
(Hz) ................................................... : See the Note on next page
Measured
current (mA) ....................................... : See the Note on next page
Measured
voltage
(V).......................................... : See the Note on next page
Measured capacitance (
µF) ................................: Measured max. 2200 pF
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A