ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
Note:
The measurement is conducted between the output connector and earth.
Model MU15-C033280-C5:
Voltage = 0.86 Vpeak, Frequency = 60 Hz, Current = 0.43 mA, Limited = 0.7 mA;
Voltage = 0.98 Vpeak, Frequency = 60 kHz, Current = 0.49 mA, Limited = 42 mA (0.7 x 60).
The measurement is conducted between CY1 secondary and earth.
Voltage = 1.02 Vpeak, Frequency = 60 Hz, Current = 0.51 mA, Limit = 0.7 mA;
Voltage = 1.18 Vpeak, Frequency = 60 kHz, Current = 0.59 mA, Limit = 42 mA (0.7
× 60).
Model MU15-C060250-C5:
Voltage = 1.02 Vpeak, Frequency = 60 Hz, Current = 0.51 mA, Limited = 0.7 mA;
Voltage = 1.4 Vpeak, Frequency = 60 kHz, Current = 0.70 mA, Limited = 42 mA (0.7 x 60).
The measurement is conducted between CY1 secondary and earth.
Voltage = 1.06 Vpeak, Frequency = 60 Hz, Current = 0.53 mA, Limit = 0.7 mA;
Voltage = 1.86 Vpeak, Frequency = 60 kHz, Current = 0.93 mA, Limit = 42 mA (0.7
× 60).
Model MU15-C240010-C5:
Voltage = 1.08 Vpeak, Frequency = 60 Hz, Current = 0.54 mA, Limited = 0.7 mA;
Voltage = 1.37 Vpeak, Frequency = 60 kHz, Current = 0.69 mA, Limited = 42 mA (0.7 x 60).
The measurement is conducted between CY1 secondary and earth.
Voltage = 1.44 Vpeak, Frequency = 60 Hz, Current = 0.57 mA, Limit = 0.7 mA;
Voltage = 1.44 Vpeak, Frequency = 60 kHz, Current = 0.72 mA, Limit = 42 mA (0.7
× 60).
2.5
Limited power sources
Inherently limited output
P
Impedance limited output
N/A
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
P
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
power (VA) .........................................................:
power (VA) .........................................................:
See the Note on next page
Current rating of overcurrent protective device (A)