L8400P - JBL Audio EMC - CB Certificate (repair manual). Page 18

Read JBL L8400P EMC - CB Certificate online

 
 
page 14 of 40 
Ref.No.:415379  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class 
Ι equipment 
reliably connected to earth terminal, within 
equipment 
Class II appliance 
 
Class 
Ι supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 N 
 
Protective earth conductors correctly coloured 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N 
 
Protective earth terminal resistant to corrosion 
 
 
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... :  N 
15.3 
Terminals for external flexible cords and for permanent connection to the mains supply 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 N 
15.3.2 Reliable 
connection 
of 
non-detachable 
cords: 
   
 
 
not soldered to conductors of a printed circuit 
board 
 P 
 
adequate clearances and creepage distances 
between connections should a wire break away 
 P 
 
wire secured by additional means to the conductor   
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
 N 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 N 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Flat pin connectors on mains 
switch 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 N 
15.3.6 
Terminals to 15.3.3 have sizes required by Table 8 No screw terminal 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 N 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 N 
Page of 46
Display