Read JBL L8400P EMC - CB Certificate online
page 14 of 40
Ref.No.:415379
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
15.2
Provision for protective earthing
Accessible conductive parts of Class
Ι equipment
reliably connected to earth terminal, within
equipment
equipment
Class II appliance
N
Class
Ι supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... : N
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2 Reliable
connection
of
non-detachable
cords:
not soldered to conductors of a printed circuit
board
board
P
adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
P
wire secured by additional means to the conductor
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Flat pin connectors on mains
switch
switch
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by Table 8 No screw terminal
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N