Read JBL L8400P EMC - CB Certificate online
page 10 of 40
Ref.No.:415379
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.2
Capacitors and RC units
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2:nd Edition :
N
14.2.2
X capacitors tested to IEC 60384-14, 2:nd Edition : Type No. XG-VS, class X2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
N
14.2.5
Capacitors with volume exceeding 1750 mm
3
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better ..................................................................... :
compliance with IEC 60384-1, 4.38 category B or
better ..................................................................... :
CXAC1 class X 2
N
Capacitors with volume exceeding 1750 mm
3
,
mounted closer to a potential ignition source than
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ....................................... :
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ....................................... :
N
Shielded by a barrier to FV 0 or metal .................. :
N
14.3
Inductors and windings
14.3.1
Transformers and inductors marked with
manufacturer’s name and type ............................. :
manufacturer’s name and type ............................. :
Power transformer PT1:
Chia Ban, 042-010160-000
Chia Ban, 042-010160-000
P
Transformers and inductors separately approved : No
N
14.3.2
Isolating transformer complies with 14.3.3,
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.3,14.3.4.1 and 14.3.5.1
P
Separating transformer complies with 14.3.3,
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
N
Flammability test of insulating material acc. to
20.1.4 (except in thin sheet form)
20.1.4 (except in thin sheet form)
P
14.3.3.1
Clearances and creepage distances according to
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
Power transformer PT1:
P
14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
Prim-sec: 10.3mm
P
Coil formers and partition walls
≥ 0.4 mm
1.61mm x 1
P