L8400P - JBL Audio EMC - CB Certificate (repair manual). Page 15

Read JBL L8400P EMC - CB Certificate online

 
 
page 11 of 40 
Ref.No.:415379  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Prim-iron core: 8.8mm 
 
Coil formers and partition walls 
≥ 0.4 mm 
1.53mm x 1 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N 
 
Component meets category FV 1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
2.5mm on PCB under fuse 
holder (reduction allowed  
according to  13.1.1) 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
 
b) Thermal cut-outs tested as part of the 
submission 
Did not operate during tests 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices resettable by soldering 
 
14.5.2.1 
Fuse-links in the mains circuit according to 
IEC 60127 
F1 P 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F1  T2.5AL  
14.5.2.3 
Not possible to connect fuses in parallel ............... : No 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ........ :
Tools are required 
Page of 46
Display