Read JBL L8400P EMC - CB Certificate online
page 11 of 40
Ref.No.:415379
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
Prim-iron core: 8.8mm
P
Coil formers and partition walls
≥ 0.4 mm
1.53mm x 1
P
14.3.5.2
Class
Ι transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category FV 1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.5
Protective devices
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
2.5mm on PCB under fuse
holder (reduction allowed
according to 13.1.1)
holder (reduction allowed
according to 13.1.1)
P
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
Did not operate during tests
N
14.5.1.2
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices resettable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
F1 P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F1 T2.5AL
P
14.5.2.3
Not possible to connect fuses in parallel ............... : No
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required
P
Click on the first or last page to see other L8400P service manuals if exist.