Read JBL EMC - CB Certificate EMC - CB Certificate online
Page 8 of
85
Report No. 17040045 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
1.5.9.2
Protection of VDRs
Protected by a current fuse
before the MOV1.
before the MOV1.
P
1.5.9.3
Bridging of functional insulation by a VDR
MOV1 used between L and N
P
1.5.9.4
Bridging of basic insulation by a VDR
No such construction
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
No such construction
N/A
1.6
Power interface
P
1.6.1
AC power distribution systems
TN power system
P
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is the
operation with the maximum
specified by the manual
instruction. (see appended table
1.6.2)
1.2.2.1 for this equipment is the
operation with the maximum
specified by the manual
instruction. (see appended table
1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
This appliance is not hand-held
equipment.
equipment.
N/A
1.6.4
Neutral conductor
The neutral conductor insulated
from earth and from the body
throughout the equipment as if
it were a line conductor
from earth and from the body
throughout the equipment as if
it were a line conductor
P
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
See below
P
1.7.1.1
Power rating marking
P
Multiple mains supply connections.........................: Single power source
P
Rated voltage(s) or voltage range(s) (V) ..............: 100-240V~
P
Symbol for nature of supply, for d.c. only ..............: AC source
N/A
Rated frequency or rated frequency range (Hz) ....: 50/60Hz
P
Rated current (mA or A) .......................................: 0.8A MAX
P
1.7.1.2
Identification markings
P
Manufacturer’s name or trade-mark or
identification mark ................................................:
identification mark ................................................:
JBL
P
Model identification or type reference ...................: See copy of marking plate
P
Symbol for Class II equipment only ......................: 60417-1-IEC-5172 symbol
marked.
P
Other markings and symbols ...............................: Additional symbol or marking
does not give rise to
misunderstanding.
misunderstanding.
P
1.7.1.3
Use of graphical symbols
N/A
Click on the first or last page to see other EMC - CB Certificate service manuals if exist.