Report No. 17040045 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
1
GENERAL
P
1.5
Components
P
1.5.1
General
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended tables 1.5.1)
P
1.5.2
Evaluation and testing of components
Components which are certified
to IEC and/or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested under
the conditions present in the
equipment.
to IEC and/or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested under
the conditions present in the
equipment.
P
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
Transformers used are suitable
for their intended application
and comply with the relevant
requirements of the standard
and particularly Annex C.
for their intended application
and comply with the relevant
requirements of the standard
and particularly Annex C.
P
1.5.5
Interconnecting cables
SELV output cable provided as
part of this equipment and no
higher energy levels than
240VA, it’s not possible to
present a hazard.
part of this equipment and no
higher energy levels than
240VA, it’s not possible to
present a hazard.
N/A
1.5.6
Capacitors bridging insulation
Between L and N: X-capacitor
(CX1) according to IEC 60384-
14 bridged.
Between primary and
secondary: Y1 capacitor (CY1,
CY2) according to IEC 60384-
14 bridged.
(CX1) according to IEC 60384-
14 bridged.
Between primary and
secondary: Y1 capacitor (CY1,
CY2) according to IEC 60384-
14 bridged.
P
1.5.7
Resistors bridging insulation
P
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
Only R1A, R1B, R2A and R2B
bridged between L and N after
fuse as functional insulation.
bridged between L and N after
fuse as functional insulation.
P
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9
Surge suppressors
Approved surge suppressor
MOV1 used
MOV1 used
P
1.5.9.1
General
Comply to Annex Q