Report No. 17040045 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
1.7.11
Durability
The label was subjected to the
permanence of marking test.
The label was rubbed with cloth
soaked with water for 15 sec.
And then again for 15 sec. With
the cloth soaked with petroleum
spirit. After this test there was
no damage to the label. The
marking on the label did not
fade. There was no curling and
lifting of the label edge.
permanence of marking test.
The label was rubbed with cloth
soaked with water for 15 sec.
And then again for 15 sec. With
the cloth soaked with petroleum
spirit. After this test there was
no damage to the label. The
marking on the label did not
fade. There was no curling and
lifting of the label edge.
P
1.7.12
Removable parts
No removable part except for
detachable plug
detachable plug
P
1.7.13
Replaceable batteries ........................................ :
No battery provided.
N/A
Language(s) ...................................................... :
1.7.14
Equipment for restricted access locations ........... :
Not intended for use in restricted
access locations.
access locations.
N/A
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
No access with test finger and
test pin to any hazardous parts.
test pin to any hazardous parts.
P
2.1.1.1
Access to energized parts
See above.
P
Test by inspection ............................................... :
P
Test with test finger (Figure 2A) ........................... :
P
Test with test pin (Figure 2B) ............................... :
P
Test with test probe (Figure 2C) .......................... :
N/A
2.1.1.2
Battery compartments
No battery compartment.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
(see appended table 2.10.5)
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
operator accessible area.
N/A
2.1.1.5
Energy hazards ................................................... : The energy does not exceed
240VA between any two points
in accessible connector of
secondary circuit.
in accessible connector of
secondary circuit.
(see appended table 2.1.1.5.)
P
2.1.1.6
Manual controls
No manual controls.
N/A
2.1.1.7
Discharge of capacitors in equipment
CX1=0.33µF,
R1A=R1B=R2A=R2B=4.7
R1A=R1B=R2A=R2B=4.7
MΩ
P