EMC - CB Certificate - JBL Audio EMC - CB Certificate (repair manual). Page 11

Read JBL EMC - CB Certificate EMC - CB Certificate online

 
 
Page 10 of 
85
                                           Report No. 17040045 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1F 
 
 
1.7.11 
Durability 
The label was subjected to the 
permanence of marking test. 
The label was rubbed with cloth 
soaked with water for 15 sec. 
And then again for 15 sec. With 
the cloth soaked with petroleum 
spirit. After this test there was 
no damage to the label. The 
marking on the label did not 
fade. There was no curling and 
lifting of the label edge. 
1.7.12 
Removable parts 
No removable part except for 
detachable plug 
1.7.13 
Replaceable batteries  ........................................ : 
No battery provided. 
N/A 
 
Language(s)  ...................................................... : 
 
 
1.7.14 
Equipment for restricted access locations ........... : 
Not intended for use in restricted 
access locations. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
No access with test finger and 
test pin to any hazardous parts.  
2.1.1.1 
Access to energized parts 
See above. 
 
Test by inspection  ............................................... :   
 
Test with test finger (Figure 2A)  ........................... :   
 
Test with test pin (Figure 2B)  ............................... :   
 
Test with test probe (Figure 2C)  .......................... :   
N/A 
2.1.1.2 
Battery compartments  
No battery compartment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
(see appended table 2.10.5)  
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
N/A 
2.1.1.5 
Energy hazards  ................................................... :  The energy does not exceed 
240VA between any two points 
in accessible connector of 
secondary circuit.  
(see appended table 2.1.1.5.) 
2.1.1.6 
Manual controls 
No manual controls. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
CX1=0.33µF, 
R1A=R1B=R2A=R2B=4.7
MΩ 
Page of 121