Report No. 17040045 001
TRF No. IEC60950_1F
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ...........................................................:
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ...........................................................:
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) ........................ : Same as applicant.
General product information:
1. The equipment model F13V-2.2C-DC is switching power supply (Direct plug-in type) for the use in
information technology equipment.
(attachment 2). The detachable British plug used in the equipment has been tested according to BS
1363-1+A4 (attachment 3). The non-detachable Japanese plug used in equipment has been tested
according to JIS C 8303 (attachment 4). The detachable Australian plug used in the equipment has
been tested according to AS/NZ 3112+A1+A2 (attachment 5). The detachable Korean plug used in the
equipment has been tested according to KSC 8305 (attachment 6). The plugs for other countries shall
be evaluated when submitted to national approval.
1363-1+A4 (attachment 3). The non-detachable Japanese plug used in equipment has been tested
according to JIS C 8303 (attachment 4). The detachable Australian plug used in the equipment has
been tested according to AS/NZ 3112+A1+A2 (attachment 5). The detachable Korean plug used in the
equipment has been tested according to KSC 8305 (attachment 6). The plugs for other countries shall
be evaluated when submitted to national approval.
5. For JP plug (non-detachable), the plug in part is integral with the enclosure and the plug portions
(incorporate pins) are moulded together with enclosure that effectively prevents any disintegration or
conductive parts remaining in the socket. For detachable plug, the plugs are fixed with enclosure by
mechanical method that effectively prevents any disintegration or conductive parts remaining in the
socket.
conductive parts remaining in the socket. For detachable plug, the plugs are fixed with enclosure by
mechanical method that effectively prevents any disintegration or conductive parts remaining in the
socket.
6. Reliability test of detachable plug also evaluated. After 200 cycles mechanical operation test, contact
resistance is in compliance with the requirement of IEC 61984. See attachment 1 for details
7. The Japanese plug shall be rotated to 90° when inserted into socket-outlet, and no hazard to be roated
to any other angle.
Abbreviations used in the report:
- normal conditions
N.C.
- single fault conditions
S.F.C
- functional insulation
OP
- basic insulation
BI
- double insulation
DI
- supplementary insulation
SI
- between parts of opposite
polarity
polarity
BOP
- reinforced insulation
RI
Indicate used abbreviations (if any)