BALBOA SUB10 (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 25

Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online

 
Page 21 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
7.1 TABLE: 
temperature 
rise measurements: Conditions 
 
 
Power consumption in the OFF/Stand-by ..........:  
 
 
Position of the functional switch (W) ..................: 0 W in 0FF-position 
— 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
1 253 50 
0.46 79  9.5  22 
253V, 1/8 of the max. non-clipping 
output power using the pink noise 
signal acc. to 4.1.6 .  
 
 
Loudspeaker impedance (Ω) .............................: 4 
— 
 
Several loudspeaker systems 
 
 
Marking of loudspeaker terminals 
 
 
 
 
Temperature Rise dT of Part
 
dT (K) 
Limit dT (K) 
Test Condition No.
No 1 
No ___ 
No ___ 
 
Iron core of mains transformer  
56 
 
 
— 
Supply cords (Not under mechanical stress) 
18 
 
 
60(50) 
PCB (supporting heat sink)  
44 
 
 
— 
Inside plastic cover 
26 
 
 
— 
Heat sink, on rear panel 
30 
 
 
40(30) 
Rear panel, near control 
26 
 
 
40 (30) 
Buttons (plastic) 
15 
 
 
50(40) 
 
 
 
 
 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ............................. :
23 
 
 
— 
— 
Ambient temperature t2 (
o
C) ............................. :
23 
 
 
— 
— 
Temperature rise dT of winding: 
(
) (
)
1
2
1
5
,
234
1
1
2
t
t
t
R
-R
R
dT
+
×
=


 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT 
(K) 
Insulation 
class 
Transformer Primary winding 
8.981 
11.23 
64 
85(75) 
Transformer Secondary winding (Yellow) 
0.582 
0.725 
53 
85(75) 
Transformer Secondary winding (Red) 
1.079 
1.300 
63 
85(75) 
Note: Permitted dT in parenthesis are for tropical climate (Singapore) 
 