Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
Strain relief device unlikely to damage flexible 
cord 
 N/A 
 
For mains cords of Class I equipment, 
hazardous live conductors become taut before 
earth conductor 
 N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or 
movement in use 
 N/A 
16.7 
Transportable musical instruments and 
amplifiers fitted with detachable cord set with 
appliance inlet to IEC 60320-1 
 N/A 
 
Transportable musical instruments and 
amplifiers fitted with detachable cord sets or 
with means of stowage to protect the cord 
 N/A 
 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
 
- screws into metal: 5 times 
 
N/A 
 
- screws into non-metallic material: 10 times 
 
17.2 
Correct introduction into female threads in non-
metallic material 
 P 
17.3 
Cover fixing screws: captive 
 
N/A 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times 
its diameter 
 P 
17.4 
No loosening of conductive parts carrying a 
current > 0,2 A 
 N/A 
17.5 
Contact pressure not transmitted through 
plastic other than ceramic for connections 
carrying a current > 0,2 A 
 N/A 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals 
not consolidated by solder 
 N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 N/A 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N/A 
17.9 
 P 
 