Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online
Page 22 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
Notes: Reference Annex D
-
CLASS I: (single phase)
AC DC
U1:
Vpk
mA rms
U1:
V
mA
U2:
Vpk
mA rms
CLASS II: (single phase)
AC DC
U1: 0.16Vpk
mA rms
U1:
V
mA
U2: 0.18Vpk
mA rms
mA
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>10
Min 2
Between parts separated by double or reinforced
insulation
insulation
>10 Min.4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120V peak
No
Between parts separated by double or reinforced insulation
4240V peak
No
Click on the first or last page to see other BALBOA SUB10 (serv.man2) service manuals if exist.