GPS 500 - Harman Kardon Car Audio EMC - CB Certificate (repair manual). Page 20

Read Harman Kardon GPS 500 EMC - CB Certificate online

 
 
<11006065 001> 
 
 
Page 9 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
After this test there was no 
damage to the labels. The 
marking on the labels did not 
fade. There was no curling or 
lifting of the label's edges. 
1.7.14 
Removable parts 
Marking is not placed on the 
replaceable snap-fit plug. 
1.7.15 
Replaceable batteries 
No batteries provided. 
 
Language(s)........................................................ :   
 
1.7.16 
Operator access with a tool ................................ :  No operator accessible area 
which needs to be accessed by 
the use of a tool. 
1.7.17 
Equipment for restricted access locations .......... :  Not limited for use in restricted 
access locations. 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
See below. 
2.1.1.1 
Access to energized parts 
No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage within the 
adapter and replaceable snap-
file connector. Any hazardous 
parts accessible are unlikely. 
Note: The width of rectangular 
gap of replaceable snap-fit 
connector is 2.8mm. 
 
Test by inspection  .............................................. :  Ditto. 
 
Test with test finger ............................................ :  Ditto. 
 
Test with test pin  ................................................ :  Ditto. 
 
Test with test probe ............................................ :  No TNV. 
2.1.1.2 
Battery compartments ........................................ :  No battery compartment. 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
 
Working voltage (Vpeak or Vrms); minimum 
distance (mm) through insulation 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
Page of 82
Display