GPS 500 - Harman Kardon Car Audio EMC - CB Certificate (repair manual). Page 24

Read Harman Kardon GPS 500 EMC - CB Certificate online

 
 
<11006065 001> 
 
 
Page 13 of 71 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.7.3 
Short-circuit backup protection 
Pluggable equipment type A. 
The building installation is 
considered as providing short-
circuit backup protection. 
2.7.4 
Number and location of protective devices ........ :  Over current protection by one 
built-in fuse F1 or one resistor 
RF if no fuse provided. 
2.7.5 
Protection by several devices 
Only one built-in current fuse or 
one resistor provided. 
2.7.6 
Warning to service personnel ............................. :  No service work necessary. 
 
2.8 
Safety interlocks 
2.8.1 
General principles 
 
2.8.2 
Protection requirements 
 
2.8.3 
Inadvertent reactivation 
 
2.8.4 
Fail-safe operation 
 
2.8.5 
Moving parts 
 
2.8.6 
Overriding  
 
2.8.7 
Switches and relays  
 
2.8.7.1 
Contact gaps (mm)  ............................................ :   
2.8.7.2 
Overload test 
 
2.8.7.3 
Endurance test 
 
2.8.7.4 
Electric strength test  
 
2.8.8 
Mechanical actuators 
 
 
2.9 
Electrical insulation 
2.9.1 
Properties of insulating materials 
Natural rubber, asbestos or 
hygroscopic materials are not 
used. 
2.9.2 
Humidity conditioning 
Carried out for 120 h 
 
Humidity (%) ....................................................... :  95 
 
 
Temperature (
°
C) ............................................... :  40 
 
2.9.3 
Grade of insulation 
Insulation materials comply with 
requirements of sub-clauses 
2.10, 4.5.1 and 5.2. 
 
2.10 
Clearances, creepage distances and distances through insulation 
2.10.1 
General  
See 2.10.3, 2.10.4 and 2.10.5. 
Page of 82
Display