Read Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate online
Report No. 078214R-RFCEP02V01
Page : 14 of 48
Version:1.0
3.
Radiated Emission
3.1. Test
Equipment
The following test equipment are used during the Radiated emission test:
Test Site
Equipment
Manufacturer
Model No./Serial No.
Last Cal.
Test Receiver
R & S
ESVS 10 / 834468/003
July, 2007
Spectrum Analyzer Advantest
R3162/ 00803480
May, 2007
Pre-Amplifier
Advantest
BB525C/ 3307A01812
May, 2007
Site # 1
Bilog Antenna
SCHAFFNER
CBL6112B / 2697
Nov., 2006
Test Receiver
R & S
ESCS 30 / 836858 / 022
Nov., 2006
Spectrum Analyzer Advantest
R3162 / 100803466
May, 2007
Pre-Amplifier Advantest BB525C/3307A01814 May,
2007
Bilog Antenna
SCHAFFNER
CBL6112B / 2705
Oct., 2006
Horn Antenna
ETS
3115 / 0005-6160
July, 2007
Site # 2
Pre-Amplifier
QTK
QTK-AMP-01/ 0001
July, 2007
Test Receiver
R & S
ESI 26 / 838786 / 004
May, 2007
Spectrum Analyzer Advantest
R3162 / 100803480
May, 2007
Pre-Amplifier
QTK
QTK-AMP-03 / 0003
May, 2007
Bilog Antenna
SCHAFFNER
CBL6112B / 2697
May, 2007
Horn Antenna
ETS
3115 / 0005-6160
July, 2007
Site # 3
Pre-Amplifier
QTK
QTK-AMP-01 / 0001
July, 2007
Note:
1. All equipments are calibrated every one year.
2. The test instruments marked by “X” are used to measure the final test results.
3.2. Test
Setup
EUT
FRP Dome
Test
Receiver
Antenna Mast
Dipole or Horn Antenna
Antenna height can be
moved from 1m to 4m,
Antenna and turntable
distance 3m
Dipole or Horn Antenna
Antenna height can be
moved from 1m to 4m,
Antenna and turntable
distance 3m
TO Controller
To Receiver
Fully Soldered Ground Plane
Non-Conducted
Table
Table
10m
1m to 4m
80cm
Load