Read Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate online
Report No. 078214R-RFCEP02V01
Page : 13 of 48
Version:1.0
2.4. Test
Procedure
AC Mains:
The EUT and simulators are connected to the main power through a line impedance stabilization
network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment.
The peripheral devices are also connected to the main power through a LISN that provides a 50ohm
/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test
setup and photographs.)
The peripheral devices are also connected to the main power through a LISN that provides a 50ohm
/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test
setup and photographs.)
Both sides of AC line are checked for maximum conducted interference. In order to find the maximum
emission, the relative positions of equipment and all of the interface cables must be changed according
to ETSI EN 301 489-1:V1.6.1 (2005-09) on conducted measurement.
The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.
emission, the relative positions of equipment and all of the interface cables must be changed according
to ETSI EN 301 489-1:V1.6.1 (2005-09) on conducted measurement.
The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.
Telecommunication Port:
The mains voltage shall be supplied to the EUT via the LISN when the measurement of
telecommunication port is performed. The common mode disturbances at the telecommunication port
shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to
the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement
is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB
LCL is wed for alternative one.
shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to
the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement
is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB
LCL is wed for alternative one.
2.5. Test
Specification
According to ETSI EN 301 489-1:V1.6.1 (2005-09)
EN 55022:1998+A1: 2000+A2: 2003
EN 55022:1998+A1: 2000+A2: 2003
2.6. Uncertainty
±
2.26 dB
2.7. Test
Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in
section 12. The acceptance criterion was met and the EUT passed the test.
section 12. The acceptance criterion was met and the EUT passed the test.
Click on the first or last page to see other DRIVE AND PLAY 2 (serv.man3) service manuals if exist.