Report Reference No.: CPSA0106916 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report EN 60065E Rev. 00 / 2004-09 
 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No N 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
 N 
19.4 
Edges or corners not hazardous 
There are no hazardous edges 
or corners when the appliance 
is operating in normal position 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surface 
19.6 
Wall or ceiling mountings adequate 
 
20 
RESISTANCE TO FIRE 
⎯ 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N 
 
b) Exemption for small components as defined in 
20.1 
 P 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
PCB base material flammability 
category V-0 or better 
(see appended table 14) 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
PCB base material flammability 
category V-0 or better 
(see appended table 14) 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
Metal enclosure has a function 
as barrier 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 N 
 
 
20.2 Fire 
enclosure 
 
⎯ 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
No voltages exceeding 4 kV 
Page of 32