SB 30 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 75

Read Harman Kardon SB 30 (serv.man3) EMC - CB Certificate online

 
ATTACHMENT 2 ( 11 / 12 ) 
Report No. : 12-1330-0135 
 
 
 
16.1 
Add the following paragraph after the third 
paragraph. 
An external earth wire of Class 0I equipment 
shall be green/yellow, and the length of the 
earth wire from the plug shall be equal or more 
than 10 cm. 
 
N/A 
16.2 
Replace the first paragraph by the following. 
Power supply cord conductors complied with 
JIS C 3662 (corresponding to IEC 60227) or 
JIS C 3663 (corresponding to IEC 60245) shall 
have a nominal cross-sectional area not less 
than those shown in table 18. If power supply 
cord conductors comply with other standards, it 
shall comply with relevant wiring requirements.  
 
N/A 
16.2 
Replace Table 18 by the following. 
 
N/A 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-sectional 
area 
 
mm
2
 
 
 
up to and including 6 
Over 6 up to and including 10 
Over 10 up to and including 16 
0,75 
1,5 
 
 
a
 The RATED CURRENT CONSUMPTION includes 
currents which can be drawn from the socket-outlets 
providing MAINS power for other apparatus. 
 
   
 
 
16.3 
In item a), replace IEC 60885-1 by JIS C 3661-
1:1998. 
 
N/A 
16.3 
In item b), replace IEC 60227-2 by JIS C 3662-
2 (corresponding to IEC 60227-2). 
 
N/A 
16.5 
Add ―or CLASS 0I EQUIPMENT used a plug 
with an external earth wire‖ after the words, 
CLASS I EQUIPMENT. 
 
N/A 
20.1.2 
In NOTE, replace ISO 1043-1 [19] by JIS K 
6899-
1:2000 [19]‖ 
 
N/A 
Annex B 
Replace normative by Informative. 
 
N/A 
Annex G 
Replace IEC 60707 by JIS C 0066:2001 
Replace IEC 60695-2-2 by JIS C 60695-2-
2:2000. 
Replace IEC 60695-11-10 by JIS Z 2391:1999. 
 
N/A 
Page of 76