ATTACHMENT 2 ( 6 / 12 )
Report No. : 12-1330-0135
Voltage U (peak)
Curve A
Curve B
142 V
1 414 V
2 828 V
11.2.1
Add the following after the original NOTE.
NOTE 2 The fuse except operating
characteristics specified in IEC 60127 shall be
tested in consideration of the characteristic.
characteristics specified in IEC 60127 shall be
tested in consideration of the characteristic.
Pass
11.2.3
Add ―and CLASS 0I‖ after the words, CLASS I.
N/A
13.4
In NOTE 2 of Table 11, replace IEC 60664-1
by JIS C 0664:2003 (corresponding to IEC
60664-1).
by JIS C 0664:2003 (corresponding to IEC
60664-1).
Pass
14.3.3.2
In the second sentence of the first paragraph,
add
add
―or JIS C 2107, JIS C 2336 and JIS C
2338‖ after the reference, IEC 60454.
N/A
14.5.1.1
In item a), ad
d ―JIS C 9730 series or‖ before
the reference, IEC 60730 series.
N/A
14.5.1.2
In item a), replace IEC 60691 by
―IEC 60691 or
JIS C 6691:2003‖...
N/A
14.5.1.2
In the first paragraph of item a), add
―or
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the
Electrical Appliance and Material
stipulating technical requirements for the
Electrical Appliance and Material
‖ after the
reference‖ to the last of the sentence.
N/A
14.5.2.1
Replace IEC 60127 by ―IEC 60127 or JIS C
6575 ‖.
6575 ‖.
N/A
14.5.2.1
In the first paragraph, add ―Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material (limited to Fuses with the rated current
of 1 A or more), or‖ after the words, ‖shall
comply with‖.
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material (limited to Fuses with the rated current
of 1 A or more), or‖ after the words, ‖shall
comply with‖.
N/A
14.5.2.2
Add the following paragraph before the last
paragraph.
paragraph.
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, only the rated current needs to be
marked.
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, only the rated current needs to be
marked.
N/A
14.5.3
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
14.5.4
Replace IEC 60127 by ―IEC 60127 or JIS C
6575 ‖.
6575 ‖.
N/A