Read Harman Kardon SB 26 (serv.man3) EMC - CB Certificate online
Page 13 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
12 Mechanical
strength
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 SUB: See below
-
12.1.1
Bump test where mass >7 kg
Approx. 9.7 kg. (SB26 SUB)
Pass
12.1.2
Vibration test
Conducted on SB26 SUB.
Pass
12.1.3
Impact hammer test
Pass
Steel ball test
2J applied to enclosure, and
then no damaged.
then no damaged.
Pass
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg Not portable.
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
N/A
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
-
13.1
Clearances in accordance with 13.3
See appended table 13.
Pass
Creepage distances in accordance with 13.4
See appended table 13.
Pass
13.2
Determination of working voltage
See appended table 13.
Pass
13.3
Clearances
See appended table 13.
Pass
13.3.1 General
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9.............:
with table 8 and, where applicable, table 9.............:
See appended table 13.
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4 Measurement
of
transient voltages
N/A
13.4
Creepage distances
See appended table 13.
Pass
Creepage distances greater than table 11 minimum
values
values
See appended table 13.
Pass
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
Click on the first or last page to see other SB 26 (serv.man3) service manuals if exist.