Read Harman Kardon SB 26 (serv.man3) EMC - CB Certificate online
Page 12 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
See appended table 10.3.
Pass
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table 10.3.
Pass
11 Fault
conditions
-
11.1
No shock hazard under fault condition
For SB26 SUB:
U1: 0.887V peak,
U2: 0.246V peak.
U1: 0.887V peak,
U2: 0.246V peak.
Pass
11.2
Heating under fault condition
Pass
Flames extinguish within 10 seconds
No flames occurred.
N/A
No hazard from softening solder
Pass
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
See appended table 11.2.
Pass
11.2.2
Temperature rise of accessible parts
See appended table 11.2.
Pass
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
See appended table 11.2.
Pass
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
See appended table 11.2.
Pass
11.2.5
Temperature rise of windings
See appended table 11.2.
Pass
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
Pass
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................:
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................:
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
See appended table 11.2.
Pass