SB 26 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon SB 26 (serv.man3) EMC - CB Certificate online

Page 12 of 40 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
See appended table 10.3. 
Pass 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
See appended table 10.3. 
Pass 
 
11 Fault 
conditions 
11.1 
No shock hazard under fault condition  
For SB26 SUB: 
U1: 0.887V peak, 
U2: 0.246V peak. 
Pass 
11.2 
Heating under fault condition  
 
Pass 
 
Flames extinguish within 10 seconds  
No flames occurred. 
N/A 
 
No hazard from softening solder  
 
Pass 
 
Soldered terminations not used  as protective 
mechanism  
 Pass 
11.2.1 
Measurement of temperature rises  
See appended table 11.2. 
Pass 
11.2.2 
Temperature rise of accessible parts  
See appended table 11.2. 
Pass 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
See appended table 11.2. 
Pass 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
See appended table 11.2. 
Pass 
11.2.5 
Temperature rise of windings  
See appended table 11.2. 
Pass 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
 N/A 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 Pass 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm² ................:
 N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 N/A 
 
Class I protective earthing maintained  
 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
See appended table 11.2. 
Pass 
 
Page of 95
Display