SB 26 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon SB 26 (serv.man3) EMC - CB Certificate online

Page 11 of 40 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Electric shock hazard under normal operating conditions 
For SB26 CNTR: Not directly connected to the mains. 
For SB26 SUB: See below 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1 
a) Open circuit voltages  
 
Pass 
 
b) Touch current measured from terminal devices 
using the network in annex D  .................................: 
U1: 0.854V peak, 
U2: 0.217V peak. 
Pass 
 
c) Discharge not exceeding 45 μC  
<45 μC. Pass 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
No hazardous live parts are 
accessible. 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
Pass 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No top ventilation. 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  ..................: 
8.3Vdc (Standby) 
16.7Vdc (Standby, with R502 
opened) 
Rating of R502, R503, R504, 
R505: 1MΩ 
Pass 
 
If C is not greater than 0,1 μF no test needed  
0.33μF. N/A 
9.1.7 
Resistance to external forces 
 
Pass 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
Pass 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
Pass 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Conducted on metal enclosure 
fixed amplify board. 
Pass 
9.2 
No hazard after removing a cover by hand  
 
N/A 
 
10 Insulation 
requirements 
For SB26 CNTR: Not directly connected to the mains. 
For SB26 SUB: See below
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation .................................................................: 
 N/A 
10.2 Humidity 
treatment 48 h or 120 h ...........................:  40
°C, 95%, 120h. 
Pass 
Page of 95
Display

Click on the first or last page to see other SB 26 (serv.man3) service manuals if exist.