Read Harman Kardon HS 300 (serv.man3) EMC - CB Certificate online
Report No. JSH006030124-001
Page 68 of 81
18.2 Diagram of Test Setup
CDN
AC
power
power
EUT
RF Generator
with amplifier
with amplifier
4dB
GRP 10cm high
wooden plane
to support The
to support The
3 cm high
wooden plane
to support EUT
wooden plane
to support EUT
power lead :
signal cable :
18.3 Test Setup and Test Procedure
The EUT was placed on an insulating support of 0.1m height above a ground reference Plane,
arranged and connected to satisfy its functional requirement.
arranged and connected to satisfy its functional requirement.
All relevant cables were provided with the appropriate coupling and decoupling
devices at a distance between 0.1m and 0.3m from the projected geometry of the EUT on an
insulating support of 0.03m height above the ground reference plane.
The frequency from 0.15MHz to 230MHz was checked.
18.3.1 Photo for test set-up
none
18.4 Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Test No.
Frequency
(MHz)
Level
V (e.m.f.)
Amplitude
modulation
Injected
point
Result Comment
1 0.15~80 3 1kHz
80%
L-N Pass
2 0.15~80 3 1kHz
80%
L-N-PE NA
18.5 Additions, Deviations and Exclusions from Standards
None
Click on the first or last page to see other HS 300 (serv.man3) service manuals if exist.