Report No. JSH006030124-001
Page 63 of 81
16.2 Block diagram of test setup
Power
Antenn
a mask
a mask
Table
amplifier
Signal
EUT
Field
Optical
Filte
Field probe
16.3 Test Setup and Test Procedure
16.3.1 Test setup
The test was conducted in an anechoic chamber which is 7m in length, 5m in width and 3m in
height to maintain a uniform field of sufficient dimensions with respect to the EUT, and also in
order to comply with various national and international laws prohibiting interference to radio
communications.
order to comply with various national and international laws prohibiting interference to radio
communications.
For the table top EUT, the equipment is placed in the test facility on a non-conducting table
0.8m high.
For the floor standing EUT, the equipment is placed in the test facility on a non-conducting
support 0.1m high.
The EUT was placed on the uniform calibrated plane which is 3V/m EM field.
Unshielded parallel wire was used during the test.
Wire is left exposed to the electromagnetic field for a distance of 1m form the EUT.