19. Voltage Dips, Short Interruptions and Voltage Variations 
Immunity Test 
 
Test result 
PASS 
 
19.1 Severity Level and Performance Criterion 
19.1.1 Test level 
 
Test level 
% UT 
Voltage dip and short interruptions 
% UT 
Duration 
(in period) 
100 
40 
60 
70 
30 
0.5 * 

10 
25 
50 
X ** 
 
Notes:   
1.“*” for 0.5 period, the test shall be made in positive and negative polarity, i.e. 
  starting at 0
° and 180°, respectively 
2. “**” means “x” is an open duration. This duration can be given in the product 
                specification.. Utilities in Europe have measured dips and short interruptions of 
                duration between ½ a period and 3000 periods, but duration less than 50 periods 
are most common. 
        3. if the EUT is tested for voltage dips of 100%, it is generally unnecessary to test for 
                other levels for the same durations. However, for some cases(safeguard systems or 
                electro-mechanical devices) it is not true. The product specification or product 
                committee shall give an indication of the applicability of this note. 
                     4. The gray rows are selected test level. 
 
19.1.2 Performance Criterion
 
 
Performance criterion C at the test level 30%, 60% 
Performance criterion B at the test level 0%. 
 