Page 14 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 Capacitors 
separately 
approved ………………...……: 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
Y1: CY501, CY502, CY503, 
CY504 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
X2: CX501, CX502, CX503 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for 
X2 …………………: 
No such component. 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or 
better ………………: 
 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or 
better ……………………………………: 
 N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal …………………………………………………….
No, electrolytic capacitor is fully 
shielded by metal case. 
N/A 
14.3 
Inductors and windings  
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
 
N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ……………………….:
Power transformer T502, T503 
Line filter LF501, LF502  
(See appended table14) 
Pass 
 
Transformers and inductors separately approved ….: No, tested with appliance 
N/A 
14.3.2 General 
 
 
Pass 
 
Insulation material complies with clause 20.1.4  
 
Pass 
14.3.3 
Constructional requirements  
 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional requirements   
Pass 
14.3.4 
Separation between windings 
 
Pass 