Page 14 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Capacitors
separately
approved ………………...……:
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ……:
Y1: CY501, CY502, CY503,
CY504
CY504
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ……:
X2: CX501, CX502, CX503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for
X2 …………………:
connected to the mains: tests for
X2 …………………:
No such component.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or
better ………………:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or
better ………………:
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or
better ……………………………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or
better ……………………………………:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal …………………………………………………….
:
metal …………………………………………………….
:
No, electrolytic capacitor is fully
shielded by metal case.
shielded by metal case.
N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ……………………….:
manufacturer's name and type ……………………….:
Power transformer T502, T503
Line filter LF501, LF502
(See appended table14)
(See appended table14)
Pass
Transformers and inductors separately approved ….: No, tested with appliance
N/A
14.3.2 General
Pass
Insulation material complies with clause 20.1.4
Pass
14.3.3
Constructional requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
Pass
14.3.3.2
Transformers meet the constructional requirements
Pass
14.3.4
Separation between windings
Pass