Page 11 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
9.1.7 
Resistance to external forces 
 
Pass 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
No damage of enclosure and no 
hazardous live parts are 
accessible. 
Pass 
 
b) Test hook of fig. 4 for 10 s (20 N)  
No hazardous live parts are 
accessible. 
Pass 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N 
Pass 
9.2 
No hazard after removing a cover by hand  
Tools required. 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ………………………………………………..
 
Pass 
10.2 
Humidity treatment 48 h or 120 h …………………….: 40℃, 95%, 120h. 
Pass 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 
Pass 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
Class II 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table) 
Pass 
 
11 Fault 
conditions 
 
11.1 
No shock hazard under fault condition  
Single fault did not cause 
excessive voltage in output 
circuits. 
Pass 
11.2 
Heating under fault condition  
 
Pass 
 
Flames extinguish within 10 seconds  
No flames 
N/A 
 
No hazard from softening solder  
No softening of solder point and 
becoming fluid 
Pass 
 
Soldered terminations not used  as protective 
mechanism  
 Pass 
11.2.1 
Measurement of temperature rises  
(see appended table) 
Pass 
11.2.2 
Temperature rise of accessible parts  
(see appended table) 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation  
(see appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min  
(see appended table) 
Pass 
Page of 64