Read Harman Kardon HS 2X0 EMC - CB Certificate online
Page 11 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
9.1.7
Resistance to external forces
Pass
a) Test probe 11 of IEC 61032 for 10 s (50 N)
No damage of enclosure and no
hazardous live parts are
accessible.
hazardous live parts are
accessible.
Pass
b) Test hook of fig. 4 for 10 s (20 N)
No hazardous live parts are
accessible.
accessible.
Pass
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N
Pass
9.2
No hazard after removing a cover by hand
Tools required.
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ………………………………………………..
:
surge test for basic and 4 MΩ min. for reinforced
insulation ………………………………………………..
:
Pass
10.2
Humidity treatment 48 h or 120 h …………………….: 40℃, 95%, 120h.
Pass
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
Pass
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table)
Pass
11 Fault
conditions
11.1
No shock hazard under fault condition
Single fault did not cause
excessive voltage in output
circuits.
excessive voltage in output
circuits.
Pass
11.2
Heating under fault condition
Pass
Flames extinguish within 10 seconds
No flames
N/A
No hazard from softening solder
No softening of solder point and
becoming fluid
becoming fluid
Pass
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
(see appended table)
Pass
11.2.2
Temperature rise of accessible parts
(see appended table)
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
(see appended table)
Pass
Click on the first or last page to see other HS 2X0 service manuals if exist.