Page 9 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Reinforced insulation > 0,4 mm (mm) ……………….: T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
Optocoupler U502, U504, U505,
U515: 0.40mm min.
U515: 0.40mm min.
Enclosure (front panel): 1.5mm
min.
Separation sheet on internal
enclosure around power board:
0.41mm min.
min.
Separation sheet on internal
enclosure around power board:
0.41mm min.
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Inside T502, T503.
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
N/A
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Pass
8.10
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Pass
8.11
Detaching of wires
No risk of any wire becoming
detached.
detached.
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
See above
Pass
Vibration test carried
out ………………………………:
out ………………………………:
No N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Pass
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Pass
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Internal wires secured and keep
enough distance from sharp or
hot parts.
enough distance from sharp or
hot parts.
Pass