Page 10 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
 N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 
Disconnect device  
The appliance coupler is used 
as the disconnect device.
 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
No such device 
 
N/A 
8.19.2 
Mains switch ON indication  
Disconnect device is appliance 
coupler 
N/A 
8.20 
Switch not fitted in the mains cord  
No such device 
N/A 
8.21 
Bridging components comply with clause 14  
No such device within the EUT 
N/A 
8.22 
Non-separable thin sheet material  
No such device within the EUT 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 
1000Vac or 1500Vdc 
N/A 
9.1.1.1 
a) Open circuit voltages  
 
Pass 
 
b) Touch current measured from terminal devices 
using the network in 
annex D …………………………: 
U1=10.3Vp  
U2=0.30Vp 
Pass 
 
c) Discharge not exceeding 45 μC  
Less than 45
μC 
Pass 
 
d) Energy of discharge not exceeding 350 mJ  
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
Pass 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No enter. 
Pass 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Test probe did not become 
hazardous live parts after test. 
Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Test probe did not become 
hazardous live parts after test. 
Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No such pre-set control used. 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s ………………:
Less than the limit.    
Discharging resistor 
R501=R502=560 kΩ max 
Pass 
 
If C is not greater than 0,1 μF no test needed  
 N/A 