Read Harman Kardon HS 2X0 EMC - CB Certificate online
Page 10 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
The appliance coupler is used
as the disconnect device.
as the disconnect device.
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
No such device
N/A
8.19.2
Mains switch ON indication
Disconnect device is appliance
coupler
coupler
N/A
8.20
Switch not fitted in the mains cord
No such device
N/A
8.21
Bridging components comply with clause 14
No such device within the EUT
N/A
8.22
Non-separable thin sheet material
No such device within the EUT
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000Vac or 1500Vdc
1000Vac or 1500Vdc
N/A
9.1.1.1
a) Open circuit voltages
Pass
b) Touch current measured from terminal devices
using the network in
annex D …………………………:
using the network in
annex D …………………………:
U1=10.3Vp
U2=0.30Vp
U2=0.30Vp
Pass
c) Discharge not exceeding 45 μC
Less than 45
μC
Pass
d) Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers
Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No enter.
Pass
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No such pre-set control used.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ………………:
of the mains plug; voltage (V) after 2 s ………………:
Less than the limit.
Discharging resistor
R501=R502=560 kΩ max
Discharging resistor
R501=R502=560 kΩ max
Pass
If C is not greater than 0,1 μF no test needed
N/A