HK 990 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 6

Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online

 
Page 5 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus  .................................: Class 
II 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 
Ventilation instructions require the use of the test 
box 
Yes 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit 
 
5.1  
a), b) 
Identification, maker, model ....................................:  HK 990, Harman/Kardon 
c) 
Class II symbol if applicable 
 
d), e) 
Rated supply voltage and symbol ..........................:  110-120V~ 
f) 
Frequency if safety dependant 
60Hz 
g), h), i) 
Rated current or power consumption .....................:  1000W 
5.2 a) 
Earth terminal 
 
N/A 
b) 
Hazardous live terminals 
 
N/A 
c) 
Supply output terminals (other than mains) 
 
N/A 
5.3 
Use of triangle with exclamation mark 
Only in schematics diagram 
5.4 
Instructions for use 
5.4.1  
a) 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled with 
liquid, etc. 
 
b) 
Hazardous live terminals, instructions for wiring 
 
N/A 
c) 
Instructions for replacing lithium battery 
 
N/A 
 
Instructions for modem if fitted 
 
N/A 
d) 
Class I earth connection warning 
 
N/A 
e) 
Instructions for multimedia system connection 
 
N/A 
f) 
Special stability warning for fixed installation 
 
N/A 
g) 
Batteries not exposed to heat/sun warning 
 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
 
 
Instructions for permanently connected equipment 
 
N/A 
 
Page of 64