Read Panasonic CS-F18DTE5 / CU-YL34HBE5 / CS-F24DTE5 / CU-YL24HBE5 / CU-YL43HBE5 / CS-F28DTE5 / CU-YL28HBE5 / CS-F34DTE5 / CS-F43DTE5 Service Manual Simplified online
CS-F24DTE5 CU-YL24HBE5
CS-F24DTE5 CU-YL43HBE5
CS-F28DTE5 CU-YL28HBE5
CS-F34DTE5 CU-YL34HBE5
CS-F43DTE5 CU-YL43HBE5
2 Service Information---------------------------------------------- 5
CS-F28DTE5 CU-L28DBE5 CS-F34DTE5 CU-L34DBE5 CS-F43DTE5 CU-L43DBE5 CS-F50DTE5 CU-
L50DBE5, Order No. MAC0504060C2 and CS-F18DTE5 CU-L34DBE5, Order No. MAC0503046C2.
5.2. CU-YL34HBE5-------------------------------------------- 14
5.3. CU-YL43HBE5-------------------------------------------- 15
6.2. CU-YL34HBE5-------------------------------------------- 17
6.3. CU-YL43HBE5-------------------------------------------- 18
7.2. CU-YL34HBE5-------------------------------------------- 20
7.3. CU-YL43HBE5-------------------------------------------- 21
8.2. CU-YL34HBE5-------------------------------------------- 23
8.3. CU-YL43HBE5-------------------------------------------- 24
9.2. CU-YL34HBE5 CU-YL43HBE5----------------------- 27
10.2. Outdoor unit installation -------------------------------- 42
11.2. Capacity And Power Consumption ------------------ 57
11.3. Safety device ---------------------------------------------- 95
11.4. Operating characteristics------------------------------- 96
11.5. Fan performance ----------------------------------------- 97
11.6. Discharge and suction pressure---------------------- 99
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
the seriousness is classified by the following indications.
2. If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring
4. Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water
6. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water
fire.
injury.
22. Must not use other parts except original parts described in catalog and manual.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some
countries, permanent connection of this room air conditioner to the power supply is prohibited.