MX-4110N, MX-4111N, MX-4112N, MX-4110FN, MX-4111FN, MX-5110N, MX-5111N, MX-5112N, MX-5110FN, MX-5111FN (serv.man116). Combined MFP Firmware Version 07.00.R1_A (Production Run Date June 2012) - Bulletin Only - Sharp Copying Equipment Technical Bulletin (repair manual)

mx-4110n, mx-4111n, mx-4112n, mx-4110fn, mx-4111fn, mx-5110n, mx-5111n, mx-5112n, mx-5110fn, mx-5111fn (serv.man116) technical bulletin
Model
MX-4110N MX-4111N MX-4112N MX-4110FN MX-4111FN MX-5110N MX-5111N MX-5112N MX-5110FN MX-5111FN (serv.man116)
Pages
3 Few pages! See other manuals at the bottom of the first or last page.
Size
27.46 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / Combined MFP Firmware Version 07.00.R1_A (Production Run Date June 2012) - Bulletin Only
File
mx-4110n-mx-4111n-mx-4112n-mx-4110fn-mx-4111fn-mx-.pdf
Date

Read Sharp MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man116) Technical Bulletin online

 
                                                                                                                                       
CCE-1037   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. Model Name: 
MX-4112N/5112N 
 
2. Description: 
Upgrade of ICU, PCL, PCU-ROM 
 
From mid-June 2012 production 
ROM control No. 
ICU 
PCL 
PCU 
SCU 
FAX 
E-Manual 
G00 
0700R1 0700R1 0110R1 0102R1 0101G1 0170R1 
 * ICU above is the version described in the ROM management label.  Check that the actual  
  version is: ICU (MAIN): 07.00.R1.00/ICU (BOOT): 01.00.R1.00/ICU (SUB): 01.04.R1.00/ 
  LANGUAGE: 01.59.A1.00/GRAPHIC: 01.00.A1.00/UICONTENTS: 07.00.R1.00; by SIM22-5.  
 * PCL above is also the version described in the ROM management label.  Check that the
actual  
  version is: PCL (MAIN): 07.00.R1.00/PCL (PROFILE): 01.00.R1.00; by SIM22-5.  
  Item of change:  See the attached sheets. 
 
 
 
 
           
                               ROM Version Combination History Table 
 
No 
ROM 
control No. 
ICU PCL PCU SCU FAX 
E-Manual 
Action 
T/R 
No 
(5) 
F00 
0600R1 0600R1 0109R1 0102R1 0101G1  0170R1 2012/3 
Mid 
CCE-1009
(4) 
E00 
0500R1 0500R1 0106R1 0102R1 0100G1  0160R1 2011/12 
Mid 
CCE-994 
(3) 
D00 
0400R1 0400R1 0105R1 0102R1 0100G1  0151R1 2011/9 
Mid CCE-961 
(2) 
C00 
0300R1 0300R1 0104R1 0101R1 0100G1  0140R1 
2011/7  CCE-937 
(1) 
B01 
0201R1 0200R1 0103R1 0101R1 0100G1  0130R1 2011/5 
Mid CCE-916 
 
 
ROM UPGRADE..... (6). 
TECHNICAL BULLETIN 
Date: 12
th
 July 2012 
Model: MX-4112/5112N 
Ref: CCE-1037 
 
Colour: White 
 
Page: 1  OF  3 
 
                                                                                                                                       
CCE-1037   
 
 
 
[Description] 
No. Item 
Details 
1 UI 
In some cases, the icon on the Home screen was not displayed.  This problem has 
been corrected.  
2 UI 
Even though the "Disable Registration of Program" was selected in System 
Settings, the user program could be deleted.  This problem has been corrected.  
(Modification has been made to prohibit the deletion of the program and the 
change of the program name when the "Disable Registration of Program" is 
selected.)   
3 UI 
When authenticating the user, if the operation was locked due to entering the 
wrong password three times, it was not unlocked even over 5 minutes passage 
after the power switch on the panel was turned OFF/ON.  This problem has been 
corrected. 
4 UI 
When the default was set to the Copy screen and the user authentication was 
enabled, if the Toner Empty occurred, the message "Change the toner cartridge" 
without the [OK] button would be displayed, and the authentication password 
could not be input.  This problem has been corrected.  <Modification has been 
made to display the message "Change the toner cartridge" with the [OK] button 
when the authentication is enabled (before log-in)>. 
5 UI 
When using MFP for a long time without entering the 1W Energy Save mode, in 
some cases, the operation panel became unresponsive.  This problem has been 
corrected. 
6 UI 
The message when entering the password for the encrypted PDF has been 
changed.  
 
[Before the change] 
Enter the password? 
[Yes] [No] 
 
[After the change] 
Please enter Password. 
[Cancel] [OK] 
7 Machine 
Control 
For the enhancement of the jam processing performance at the fusing section, the 
modification has been made to perform the operation of the fusing pressure 
release also when the paper jam occurs with OHP/Glossy paper mode. 
8 Machine 
Control 
There were some cases where the temperature correction for the LSU registration 
adjustment did not work correctly under the influence of the dehumidification 
heater, which would lead up to the registration shift.  For the reason above, the 
modification has been made to get the LSU temperature correction to work 
properly when the dehumidification heater is ON and when it is OFF.   
9 Machine 
Control 
As the prevention measures of "F2-6*", the following sequence has been added in 
to the toner replenishing operation:    
To repeat the negative rotation/ positive rotation of the toner motor several times 
10 
Authentication 
Control 
When the user name could not be taken from LDAP with the network 
authentication, the first 16- character of the log-in name used for the network 
authentication was previously used.  Now the modification has been made to use 
the log-in name directly without cutting off at the first 16-character. 
11 
Authentication 
Control 
When registering the IC Card on User List in System Settings, if the IC card was 
set to the card reader before the operation of the card registration was performed, 
the IC Card could not be registered.   
This problem has been corrected. 
12 
Authentication 
Control 
When the log-in user did not conduct the appropriate log-out processing and left 
the machine with the error like Cover Open displayed on the operation panel, the 
next user could not log in.  This problem has been corrected.  
13 Copier 
Modification has been made to store also the paper size for the bypass tray on 
Copy Job Program. 
14 
Copier 
When turning OFF/ON the machine after the custom paper size was registered as 
 
                                                                                                                                       
CCE-1037   
 
 
 
the Inch-size, the data would be printed only in the smaller area than the area of 
the registered size.  This problem has been corrected. 
 
 
 
No. Item 
Details 
15 Printer 
With the user authentication, the log-in name which would be recorded to the job 
log when the invalid user executes the print job under the condition that the 
invalid user is able to print ("Disable Printing by Invalid User" is OFF) has been 
changed as below: 
 
[Before the change] 
User Unknown/ PC Login Name 
 
[After the change] 
User Name specified on the driver/ Login Name specified on the driver 
16 Printer 
When printing the special data that the specification of the number of download 
font was 65535, the PCL XL error occurred.  This problem has been corrected. 
17 Network 
When using "Scan to Network Folder", if the Network Folder was specified not 
with the IP address but with the server name (15 characters for the hostname), in 
some cases, the machine hanged up and could not send the data.  This problem 
has been corrected. 
18 Network 
There were some cases where Scan to E-Mail failed under the network 
environment that a large amount of ARP packets were running.  This problem has 
been corrected. 
19 Network 
20 Network 
When editing the address from the Web Page of the machine, it was slow to 
display the certain address. 
This problem has been corrected. 
21 Network 
When scanning with OSA, if the application server was Microsoft-IIS/Ver.7.0 or 
later version, the communication error occurred during the data sending by HTTP.  
This problem has been corrected. 
22 Sharp 
Desk 
Mobile 
Modification has been made not to display the registration confirmation message 
on the operation panel of the main unit when registering the profile with Scan 
function of Sharp Desk Mobile. 
23 Other 
As the further improvement of the issue that it took some time to browse the data 
in the NAS folder when using NAS function of the machine, the SMB protocol 
control and file access control have been more improved. 
24 Other 
When the "Tray Auto Switch" setting is OFF, the fusing cleaning page would be 
output as the blank page.  This problem has been corrected.  
25 Other 
In the environment where more than 1,000 users log on to one MFP with the 
authentication like schools, in some cases, the U2 error message would appear 
even though the U2 error did not occur.  This problem has been corrected.  
26 Other 
Modification has been made to change the frequency to obtain the information of 
the remaining toner using MIB with SOFT SW (SIM55-3).   
 
 SW No. 32  Data 2 
  0: every 25% (Default) 
  1: every 5% 
 
 
 
 
 
Page of 3
Display

Download Sharp MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man116) Technical Bulletin

Here you can read online and download Sharp MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man116) Technical Bulletin in PDF. MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man116) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man116) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.