HK 3480 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon HK 3480 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 7 of 36 - 
 
 
   
 Order 
No. 
14648
 
 
 
7.1  
 
 
Standby mode: 
 U 
= 
207,0
 V, I 
= 
0,008
 A, P 
= 
1,0 
W, 
Pout = 
 
W 
 U 
= 
230,0
 V, I 
= 
0,009
 A, P 
= 
1,2 
W, 
Pout = 
 
W 
U = 
254,4
 V, I 
= 
0,010
 A, P 
= 
1,6 
W, 
Pout = 
 
W 
 
 
Measured at maximum non-clipped output:   
 U 
= 
207,0
 V, I 
= 
 
3,51
 A, P 
= 
626 
W, 
Pout = 
2 x 95,6 
(SPK 1)
 
   
 
 
 
 
 
 
2 x 95,6
 W 
(SPK 2)
 
 U 
= 
230,0
 V, I 
= 
 
3,73
 A, P 
= 
734
 
W, 
Pout = 
2 x 95,6 
(SPK 1)
 
   
 
 
 
 
 
 
2 x 95,6
 W 
(SPK 2)
 
U = 
254,4
 V, I 
= 
 
3,78
 A, P 
= 
816 
W, 
Pout = 
2 x 95,6 
(SPK 1)
 
   
 
 
 
 
 
 
2 x 95,6
 W 
(SPK 2)
 
 
 
 
LSL =
 
  4 x 8
 
 
 
 
Measured at 1/8 of maximum non-clipped output:   
 U 
= 
207,0
 V, I 
= 
 
1,59
 A, P 
= 
256 
W, 
Pout = 
2 x 11,95 
(SPK 1)
 
   
 
 
 
 
 
 
 
2 x 11,95
 W 
(SPK 2)
 
 U 
= 
230,0
 V, I 
= 
 
1,63
 A, P 
= 
289
 
W, 
Pout = 
2 x 11,95 
(SPK 1)
 
   
 
 
 
 
 
 
 
2 x 11,95
 W 
(SPK 2)
 
U = 
254,4
 V, I 
= 
 
1,67
 A, P 
= 
326 
W, 
Pout = 
2 x 11,95 
(SPK 1)
 
   
 
 
 
 
 
 
 
2 x 11,95
 W 
(SPK 2)
 
 
 
 
LSL =
 
  4 x 8
 
 
 
 
 
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output): 
U = 
254,4
 V, I 
= 
 
1,67
 A, P 
= 
326 
W, 
Pout = 
2 x 11,95 
(SPK 1)
 
   
 
 
 
 
 
 
 
2 x 11,95
 W 
(SPK 2)
 
 
 
 
LSL =
 
  4 x 8
 
 
 
 
 
 
Page of 49