IEC 60065, 6th edition : 1998
 - 
- Page 9 of 36 - 
 
 
   
 Order 
No. 
14648
 
 
 
HEATING  
 
∆t =    ( R2 - R1)        x (234,5 + t1) - (t2 - t1) 
                              R1 
t1 =   
25,3 °C 
25,3 °C
 
 
t2 =   
26,5 °C 
25,3 °C
 
 
Test voltage   
207 V 
254,4 V
 
 
Winding 
R1/
Ω R2/Ω 
∆t measured 
∆t allowed *) 
Insulation 
class 
  Main transf. pr. winding (207V) 
3,88 
4,97 
71,8 
95 
Class B 
  Sub transf. pr. winding (207V) 
2846 
3274 
37,9 
85 
Class E 
 
 
 
 
 
 
  Main transf. pr. winding (254,4V) 
3,88 
5,12 
83,0 
95 
Class B 
  Sub transf. pr. winding (254,4V) 
2846 
3401 
50,7 
85 
Class E 
Other measured parts 
∆t measured 
at 207V 
∆t measured 
at 254,4V 
∆t allowed *) 
Main transformer core 
54,4 
62,5 
95 
Sub transformer core 
32,7 
41,1 
85 
Diode, D601 body 
58,0 
62,7 
PWB near D601 
47,2 
50,0 
85 
PWB near Q321 
49,3 
62,7 
85 
Regulator, IC65 heat-sink 
32,1 
46,6 
TR, Q319 body 
54,5 
71,0 
PWB near Q319 
38,1 
48,1 
85 
E. Capacitor, C601 body 
24,1 
27,4 
Main heat-sink 
51,9 
64,9 
Power cord bushing 
17,8 
19,6 
60 
Top enclosure above main heat-sink 
30,5 
36,1 
65 **) 
Top enclosure above main transformer 
24,0 
28,0 
40 
Switch button 
0,4 
0,8 
50 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.   
 
Test wall condition: 50 cm at top, 10 cm at other side 
 
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
**) Directly covering part for heat-sink.    The top cover is supplied with ventilation 
openings covering most of the top cover. This indicate emission of heat from internal 
parts and the opening area is therefore not likely to be touched during normal use.
 
 
 
 
Page of 49
Display