Read Harman Kardon HK 3480 EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 36 -
Order
No.
14648
7.1
Loudspeaker
system(s)
Right and Left for SPEAKER 1,
Right and Left for SPEAKER 2.
Marking of loudspeaker terminals
SPEAKER 1 ( 8
Ω ),
SPEAKER 2 ( 8
Ω ).
U =
254,4
V
6 Ohm
8 Ohm
16 Ohm
left left right
right
left
right
left
right
Measured max. output voltage in Vp
SP. 1) 39,1
SP. 2) 39,1
SP. 2) 39,1
SP. 1) 39,1
SP. 2) 39,1
SP. 2) 39,1
Measured max. output power in W
SP. 1) 95,6
SP. 2) 95,6
SP. 2) 95,6
SP. 1) 95,6
SP. 2) 95,6
SP. 2) 95,6
Measured max. mains power in W
816
7.1
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
Click on the first or last page to see other HK 3480 service manuals if exist.