Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 18 of 43 -
Report
No.
98502
14.4
High voltage components
No high-voltage
components
components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal links and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across
the device when opened
requirement of clause 13 for the voltage across
the device when opened
Certified protective devices
applied.
See appended table, list of
critical component.
applied.
See appended table, list of
critical component.
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs.
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
The thermal links in
main and sub transformer
separately approved.
See appended table, list of
critical components
main and sub transformer
separately approved.
See appended table, list of
critical components
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable
re-settable
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved
components according to
IEC 60127.
components according to
IEC 60127.
See list of critical components
P
14.5.2.2
Correct marking of fuse-links adjacent to holder
................................................................................. :
................................................................................. :
Correct marking applied
close to the fuse;
F101: T4A L 250V,
F102: T2.5A L 250V,
F603, F604: T6.3A L 250V
close to the fuse;
F101: T4A L 250V,
F102: T2.5A L 250V,
F603, F604: T6.3A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ......... :
No fuses holder so
designed that fuse-links
can be connected in parallel
designed that fuse-links
can be connected in parallel
P
Click on the first or last page to see other HK 3390 service manuals if exist.