Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 19 of 43 -
Report
No.
98502
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .. :
replacing fuse-links without the use of a tool .. :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
Yes, mains switch and relay
provided. Certified acc. to
IEC61058-1.
- Mains relay, certified by
SEMKO.
- Mains switch, certified by
FIMKO.
See appended table, list of
critical components.
provided. Certified acc. to
IEC61058-1.
- Mains relay, certified by
SEMKO.
- Mains switch, certified by
FIMKO.
See appended table, list of
critical components.
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved relay.
N/A