Read Harman Kardon HD 990 (serv.man4) EMC - CB Certificate online
Page 15 of 51 Report No. SH08090331-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
Pass
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
Pass
15
TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
Mains plug approved
Pass
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
Pass
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
Class II
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω
at 25 A ....................:
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
Pass
15.3.1
Adequate terminals for connection of permanent
wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
Pass
Not soldered to conductors of a printed circuit
board
No.
Pass
Adequate clearances and creepage distances
between connections should a wire break away
Pass
Wire secured by additional means to the conductor Mating lock connector
Pass