Report No. JSH0503351-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065F
TRF originator BEAB
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
Pass
Terminals located and shielded: test with 8 mm
strand
strand
Pass
15.4
Devices forming a part of the mains plug
No such device existed.
N/A
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ................................ ..................... :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ................................ ..................... :
PVC
Pass
Non-detachable cords for Class I have green/yellow
core for protective earth
core for protective earth
Class II equipment.
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
(See appended table 14)
Pass
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No such kind of flexible cords
used.
used.
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
Pass
Not possible to push cord back into equipment
Pass
Strain relief device unlikely to damage flexible cord
Pass
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N/A