Read Harman Kardon HD 970 (serv.man7) EMC - CB Certificate online
Page 16 of 55
Report No. JSH0503351-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065F
TRF originator BEAB
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω
at 25 A ............... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
Pass
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
It is not a permanently
connected apparatus.
connected apparatus.
N/A
15.3.2
Reliable connection of non-detachable cords:
Pass
Not soldered to conductors of a printed circuit
board
board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
Pass
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
to soldering or held in place by additional means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Pass
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
Pass
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
Not transmitted by insulating
material.
material.
Pass