Page 20 of 55
Report No. JSH0503351-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065F
TRF originator BEAB
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No voltage exceeding 4kV
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
All PCBs V -0.
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No part exceeds 400V
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
PCB and transformer bobbin
rated V-0.
rated V-0.
Pass
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltage exceeding 4kV
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A