HD 970 (serv.man7) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 21

Read Harman Kardon HD 970 (serv.man7) EMC - CB Certificate online

 
 
Page 20 of 55 
Report No. JSH0503351-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark  
Verdict 
 
TRF No:  IECEN60065F 
TRF originator BEAB 
 
 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
No voltage exceeding 4kV 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak)  a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
All PCBs V -0. 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
No part exceeds 400V  
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
PCB and transformer bobbin 
rated V-0. 
Pass 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
N/A 
20.2 
Fire enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
No voltage exceeding 4kV 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 
N/A 
 
Page of 61
Display

Click on the first or last page to see other HD 970 (serv.man7) service manuals if exist.