Read Harman Kardon HD 950 (serv.man3) EMC - CB Certificate online
Page 27 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of TR1 separated by basic or supplementary
insulation
insulation
3220Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply .................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
Ambient temperature (
o
C) ...................................... : 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
D8
SC
264
2 min.
FU1
0.034
P=4.0W, circuit protected, no
high temperature, no hazard.
Recoverable after fault
removed.
high temperature, no hazard.
Recoverable after fault
removed.
Pass
2.
EC5 SC
264
2 min.
FU1
0.033
P=3.8W, circuit protected, no
high temperature, no hazard.
Recoverable after fault
removed.
high temperature, no hazard.
Recoverable after fault
removed.
Pass
3.
D10
SC
264 2
min.
FU1
0
P=0W, circuit protected, no
high temperature, no hazard.
Recoverable after fault
removed.
high temperature, no hazard.
Recoverable after fault
removed.
Pass
4.
EC10
SC
264
2 min.
FU1
0.085→
0
P=11.3W, 30s, P=0W. D10
damaged, no extreme high
temperature, no hazard.
damaged, no extreme high
temperature, no hazard.
Pass
5.
D11
SC
264 2
min.
FU1
0
P=0W, circuit protected, no
high temperature, no hazard.
Recoverable after fault
removed.
high temperature, no hazard.
Recoverable after fault
removed.
Pass
6.
D12
SC
264 30
min.
FU1
0.134
P=19.6W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
7.
EC15
SC
264 2
min.
FU1
0.031
P=3.6W, circuit protected, no
high temperature, no hazard.
Recoverable after fault
removed.
high temperature, no hazard.
Recoverable after fault
removed.
Pass
Click on the first or last page to see other HD 950 (serv.man3) service manuals if exist.